15.7 CHECKING THE AUTOMATIC CONDENSATION EMPTYING FOR COMPRESSOR AND DRYER (IF AVAILABLE)
BEFORE CARRYING OUT ANY MAINTENANCE IT IS OBLIGATORY TO STOP THE MACHINE AND DISCONNECT IT FROM
THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION NETWORK.
The automatic condensation drain
Proceed as follows:
- Open the panel Ref. 2 and Ref. 10 Fig. 20.
- Press the "TEST" button, Ref. 1 (compressor and dryer) Fig. 20, for a few seconds to check if the condensation is correctly emptied from
the drainage pipe Ref. 3.
- Close the panel Ref. 2 and Ref. 10 Fig. 20.
6
15.8 CLEAN THE DIRT COLLECTION FILTER FOR COMPRESSOR AND DRYER (IF AVAILABLE)
Proceed as follows:
- Close the tap Ref. 5 Ref. 20
- Depressurise the dryer (or the WSD Ref. 11 Fig. 20 if the dryer isn't available) by pressing the "TEST" condensation emptying button (for
about 10-20 seconds) Ref. 1 Fig.20
- Switch off the machine with pushbutton Ref. 6 Fig. 20: in this way the machine stops after idle time running.
- Turn off the disconnect switch, Ref. 7 Fig. 20.
- Remove the stopper Ref. 8 Fig. 20
- Remove the filter Ref. 9 Fig. 20
- Clean the filter with a jet of air, working from inside to outside
- Install the filter, fix the plug.
32 - Edition 02/2018 Cod. 9828093052 04 -
Rif. 1 every 500 hours Fig. 20.