20.3 CHECK THE DIRECTION OF ROTATION
- Check that all fixed guards are in their correct position.
- Connect the control board to the power supply with the automatic circuit-breaker switch of the line Rif. 1 Fig. 25.
- Check the direction of rotation (following the arrow on the motor Rif. 3 Fig. 25). By pressing the "Start" button Rif. 2 Fig. 25, followed
immediately by the emergency stop Rif. 4 Fig. 25. If it does not spin in the right direction reverse two mains cables. When it rotates in the
correct direction, the oil level Rif. 5 Fig. 25. Should drop after 4 or 5 seconds of operation. It is very important to remember to check the
direction of rotation of the fan (shown by an arrow on the fan Rif. 6 Fig. 25).
ALL WORK ON THE ELECTRIC PLANT, HOWEVER SLIGHT, MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED
PERSONNEL.
T IS ADVISABLE NOT TO DO ANYTHING ON THE MACHINE PANEL
- I
IF ALL THE INSTRUCTIONS FOUND IN THIS MANUAL HAVE BEEN OBSERVED THE MACHINE CAN BE STARTED.
ATTENTION: wait al least 90 seconds before starting the machine after a switch off