Trouble
3. Dispensed product car-
bonation too low.
4. Dispensed product
comes out of dispensing
valve clear but foams in
cup or glass.
NOTE: Crushed ice also causes dispensing problems. When finished drink hits
sharp edges of ice, carbonation is released from dispensed drink.
© 2002, IMI Cornelius Inc.
TROUBLESHOOTING POST-MIX SYSTEM
Probable Cause
A. Primary CO
regulator
2
out of adjustment for
existing water conditions
or temperature.
B. CO
supply depleted.
2
C. Air in carbonator water
tank.
D. Water, oil, or dirt, in CO
supply.
A. Oil film or soap scum in
cups or glasses.
B. Ice used for finished drink
is sub-cooled.
Olympus Post-Mix Service Manual
Remedy
A. Adjust primary CO
lator. As instructed.
B. Replenish CO
C. Vent air out of carbonator
water tank through relief
valve. Open No. 1 dis-
pensing valve to make
carbonator water pump
cycle on.
D. Remove contaminated
CO
. Clean CO
2
2
(lines, regulator, etc.)
using a mild detergent
solution. Install a clean
CO
supply.
2
A. Use clean cups or
glasses.
B. Do not use ice directly
from freezer. Allow ice to
become "wet" before
using. (Refer to following
NOTE).
- 21 -
regu-
2
supply.
2
system
2
Publication Number: 750300229