Cornelius REMCOR OLYMPUS POST-MIX Service Manual page 18

Table of Contents

Advertisement

Olympus Post-Mix Service Manual
LED Diagnostics
LED diagnostic lights are mounted on the control board to assist in troubleshooting. There is one green
LED and one red LED.
Green LED
Functions of the LEDs are:
Red and Green OFF = no power to the dispenser
Green ON = line voltage is within acceptable range
Red ON = a fault condition, including carbonator pump running for more than 3 minutes, ice bank con-
trol calling for the compressor within the 3 minute startup delay period.
NOTE: The control board must be reset if the carbonator pump does not run because the 3-
minute continuous run period has been exceeded (red LED ON). To reset the control board toggle
the main power switch
Publication Number: 750300229
OFF
, wait 15 seconds, then toggle to
- 14 -
Red LED
ON
.
© 2002, IMI Cornelius Inc.