Trouble Shooting - Cornelius REMCOR OLYMPUS POST-MIX Service Manual

Table of Contents

Advertisement

Olympus Post-Mix Service Manual
IMPORTANT: Only a service person should service internal components or electrical wiring.
IMPORTANT: If repairs are to be made to one of the syrup circuits. disconnect applicable syrup tank and
bleed pressure from the system before proceeding.
IMPORTANT: If repairs will be made to the CO2 or carbonated water systems, disconnect electrical
power to the carbonator, shut off CO2 and water supplies, then bleed systems before proceeding.
WARNING
any electrical repairs or working on the internal parts of the unit.
Trouble
1. Adjustment of dispensing
valve syrup flow regulator
does not increase to
desired water-to-syrup
ratio.
2. Adjustment of dispensing
valve syrup flow regulator
does not decrease to
desired water-to-syrup
ratio.
Publication Number: 750300229

TROUBLE SHOOTING

— To avoid personal injury disconnect electrical power to the unit before attempting
TROUBLESHOOTING POST-MIX SYSTEM
Probable Cause
A. No syrup supply.
B. Syrup supply container
not securely connected
into system.
C. Tanks System –
Syrup tanks secondary
CO2 regulator out of
adjustment.
Bag-in-Box System –
Primary CO2 regulator
out of adjustment.
D. Inoperative dispensing
valve syrup flow control.
E. Tapered washer inside
tube swivel nut connec-
tion distorted from being
over tightened restricting
syrup flow.
A. Dirty or inoperative dis-
pensing valve syrup flow
control.
Remedy
A. Replenish syrup supply.
B. Securely connect syrup
supply container into
syrup system.
C. Adjust syrup tanks sec-
ondary CO
instructed.
Adjust primary CO
lator as instructed.
D. Repair dispensing valve
syrup flow control.
E. Replace tapered gasket.
Make sure it seats prop-
erly.
A. Disassemble clean and
sanitize dispensing valve
syrup flow control.
- 20 -
regulator as
2
regu-
2
© 2002, IMI Cornelius Inc.