Check Ratio

Check the ratio whenever flavors are changed or any service is preformed.

Clean Condenser

Accumulation of dust and grease on the refrigeration condenser can cause overheating. The condenser
should be cleaned as often as necessary to avoid overheating using the following procedure.
1. Disconnect electrical power to the dispenser.
2. Remove top panel (one screw). Disconnect wires to On/Off and Keylock switches.
3. Remove merchandiser (and wires if illuminated).
4. Vacuum or use a soft brush to clean condenser coil. If available, use low pressure compressed air.
5. Clean around top of refrigeration assembly.
6. Reinstall merchandiser, wires to switches and top panel.
© 2002, IMI Cornelius Inc.
Olympus Post-Mix Service Manual
- 19 -
Publication Number: 750300229