Olympus Post-Mix Service Manual
3. CO
is used to drive the syrup mini-pumps. Connect the CO
2
Incoming CO2 line
Mini-pumps
4. The syrup supply lines must connect directly to the mini-pumps. The mini-pump outlets connect to the
dispenser syrup inlet fittings. These connections are factory assembled. With this in mind, connect
syrup, water and drain lines and fill the water bath following the instructions in Section 3.2.
NOTE: When cutting the hoses be sure to leave enough length so that the mini-pumps can be
removed and worked on.l
Mini-pumps
removed and set
on top of drip tray
5. Connect electrical power following the instructions in Section 3.3.
6. Check for leaks following the instructions in Section 3.4.
7. Reinstall the mini-pump assembly and cover plate.
NOTE: Be sure lines do not kink as the assembly is reinstalled.
8. When the water bath is cool, ratio the valves.
NOTE: If there is a problem with ratioing the valves one possible problem is a blocked or
restricted mini-pump.
Publication Number: 750300229
tee to the CO
2
CO2 line to carbonator
CO2 tee
CO2 line to operate
mini-pump
Mini-pump inlets
Syrup supply lines
must be long enough
to allow mini-pump
removal
- 12 -
line (see below).
2