Christie J Series Setup Manual page 40

Hide thumbs Also See for J Series:
Table of Contents

Advertisement

Section 4: Maintenance
Check Liquid Coolant Level
1. Remove the 3 stacking mounts, if installed.
2. Release the 8 quick release screws that secure the top cover.
3. Lift the top cover off and set aside.
4. Locate the Liquid Cooling Module and inspect the liquid level window.
window which indicates the "MIN FILL LEVEL". Refer to
5. If coolant is below the "MIN FILL LEVEL" add more coolant.
Refilling Liquid Coolant Module
1. Using a flat head screwdriver, remove the fill port cap and the air vent cap. See
2. Using a funnel and coolant, fill the liquid cooling module until the coolant is within 2mm of the top cover.
3. Using a flat head screwdriver, replace the fill port cap and the air vent cap.
NOTE:
If refilling the liquid coolant module outside of the projector, the level of coolant can be seen by looking
through the liquid level window.
Remove the Liquid Coolant Module from the Projector (Optional)
1. Using a 6mm hex driver or Allen key, remove the 2 bolts securing the top frame bracket. Refer to
8
. (LEFT)
2. Disconnect the electrical connector by depressing the lock tab and pulling.
3. Disconnect the liquid connectors from the liquid coolant module by pushing and turning counterclockwise.
NOTE:
The connectors are leak free and will not leak when connecting or disconnecting.
4. Using a 3mm hex driver or Allen key, remove the 4 screws securing the liquid coolant module to the
projector. Refer to
5. Carefully lift the liquid coolant module out of the projector.
6. Check liquid coolant level as above.
7. If necessary, refill the liquid coolant as above.
8. Replace the liquid coolant module by reversing steps 1-5 above.
4-6
F
Figure 4-8 .
(RIGHT)
Figure
4-7
IGURE
NOTE:
The arrow is next to the
4-7.
Figure
4-7.
J Series 2.0, 2.4, and 3.0 kW Setup Guide
020-100751-01 Rev. 1 (10-2011)
Figure 4-