Fujitsu FI-4860C2 Operator's Manual page 153

Image scanner
Hide thumbs Also See for FI-4860C2:
Table of Contents

Advertisement

6.
Attach the Lamp socket cover in the reverse order of its removal. Make
sure that the metal part is fixed firmly.
Lamp socket cover
7.
Close the glass sheet guide. Make sure that the guide is fixed firmly.
8.
Lift the Upper transport unit a little to release the safety lock and then
lower the unit slowly, then push the unit to close it completely.
9.
Clear the Front-side lamp counter.
Please refer to the section "7.3 Setup Mode Details", " 9. Abrasion counter
(Abrasion CNT) reset " on page 7-33.
You can check the cumulative lamp-on time from the Operator
panel Test mode.
HINT
For the details, refer to the section "7.5 Test Mode Details " " 3.
Display the cumulative lamp-on time " on page 7-81.
4.6 Replacing the Front-side Lamp
4
4-19