Operation; Display During Operation; Display During Regeneration; Controller Operation During Programming - Pentair FOLEO 5800 XTR Installer Manual

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Installer manual Foleo 5800 XTR - Operation
7

Operation

7.1

Display during operation

7.2

Display during regeneration

During regeneration, the regeneration cycle wheel shows the regeneration step the valve is
advancing to, or has reached (green), and the time remaining in that step (1). Once all
regeneration steps are complete the valve returns to treatment position and resumes normal
operation. The time remaining in regeneration will be displayed on the home screen in hours and
minutes.
Pressing the
button during a regeneration cycle immediately advances the valve to the next
cycle step position and resumes normal step timing. The
is in position and the motor has stopped.
7.3

Controller operation during programming

The controller can only be programmed with the valve in treatment. While being programmed the
controller continues to operate normally, monitoring water usage and keeping all displays up to
date. Controller programming is stored in memory permanently until reset.
66 / 108
Water treatment
wed
12:01 am
treatment
rapid rince
backwash
draw
Water treatment
treatment
rapid rince
backwash
draw
4.5
tank refill
pause
48 m
34 s
tank refill
pause
button is only shown when the valve