8.5.7.4
Chlorine generator cleaning/replacement
1. Remove the softener cover, see First steps [
[
Page 75].
2. Disconnect the tube
3. Unscrew the BLFC holder
4. Remove the nut (6), washer (5), o-ring
support (1).
5. Unscrew the chlorine generator
6. Clean or replace the chlorine generator (8).
7. Lubricate the seals
Caution - material
Using another type of lubricant, such as petroleum-based lubricants (Vaseline, oils, or
hydro-carbon-based lubricants) or silicone grease, may damage the valve.
8. Reverse above procedure steps to rebuild.
Caution - material
To avoid any damage, the chlorine generator (8) must be installed horizontally or
slightly inclined downwards, as shown in the following illustration.
Caution - material
The controller must be set with chlorine generator, see Chlorine generation screen
[
Page 58].
Ref. MKT-IM-038 / E - 22.10.2021
(14)
(push fit system (13)).
(12)
from chlorine generator (8).
(4)
(8)
from its elbow (3).
(2+4+7+9)
with approved P-80
Installer manual Foleo 5800 XTR - Maintenance
Page 74] and Softener cover removal
and chlorine generator
®
Emulsion lubricant only.
(8)
with its elbow
(3)
from
85 / 108