Pentair FOLEO 5800 XTR Installer Manual page 96

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Installer manual Foleo 5800 XTR - Troubleshooting
Issue
Run out of
conditioned water
between
regenerations.
Brine tank overflow. Air leak in brine line.
96 / 108
Cause
Improper regeneration.
Incorrect brine setting.
Incorrect hardness or capacity
settings.
Water hardness has increased.
Restricted meter turbine rotation
due to foreign matter in meter.
Too much water used between the
first cycle of regeneration and brine
draw.
Incorrect BLFC size with regards to
injector size.
BLFC/DLFC causing inconsistent
brine draw clogged with resin or
other debris.
Incorrect controller settings.
Injector plugged causing refill
instead of drawing.
Reset and recovery
Control brine dosage set and repeat
regeneration.
Set brine to proper level. See Valve
screen [
Page 51].
Set hardness and capacity settings
Regeneration screen [
Format screen [
Page 44].
Check hardness settings. See
Regeneration screen [
Remove meter housing, free up
turbine and flush with clean water.
Turbine should spin freely. If not,
replace meter.
Set regeneration times at low or no
water usage. See Regeneration
screen [
Page 53].
Eventually installing the optional
®
Pentair
fast brine valve will be
necessary. Contact your supplier.
Check all connections in brine line
for any leaks.
Use of too small BLFC with large
injector will reduce draw rates.
Clean BLFC & DLFC.
Check that controller setting match
with your actual softener model and/
or valve configuration.
Clean injector.
See Injector and injector screen
cleaning [
Page 78].
Ref. MKT-IM-038 / E - 22.10.2021