Installer manual Foleo 5800 XTR - Programming
Press
to save and pass to the next screen or press
without saving.
media volume: Set to 10L, 15L, 20L or 28L, respectively for Foleo 10, Foleo 15, Foleo 20 and Foleo
30.
salt dosage: Adjust the salt dosage from 80 to 200 mg/L, depending of hardness water outlet
desired.
blfc size: BLFC size set to 0.500 gpm as standard. For Foleo 10 and 15 models, set to 0.125 gpm.
For Foleo 20 and 30 models, set to 0.25 gpm.
Press
to save and pass to the next screen or press
without saving.
capacity: Set to 484 g as equivalent CaCO
or 1355 g as equivalent CaCO
hardness: Set to system inlet water hardness.
sensor sensitivity: Option not available.
Press
to save and pass to the next screen or press
without saving.
52 / 108
Valve
media volume
salt dosage
blfc size
Valve
capacity
hardness
sensor
sensitivity
, 726 g as equivalent CaCO
3
, respectively for Foleo 10, Foleo 15, Foleo 20 and Foleo 30.
3
to return to the master settings screen
10
L
80
g/L
0.500
gpm
to return to the master settings screen
484
g
300 mg/L
na.
, 968 g as equivalent CaCO
3
to return to the master settings screen
Ref. MKT-IM-038 / E - 22.10.2021