Installer manual Foleo 5800 XTR - Programming
5.5

Diagnostics

The controller records and displays a variety of diagnostic data to assist with troubleshooting
performance issues and fine-tuning system efficiency.
From the master settings or home screens, press the diagnostics button
diagnostics screen.
Press the screen navigation arrows at the upper-right and left of the screen to view each
diagnostic parameter.
Press the home button
Info
If a regeneration is scheduled to occur while in the Diagnostic screen, the scheduled
regeneration will start as soon as exit the diagnostic.
Only Peak Flow and Totalizer can be changed, they can be reset to zero by entering the
parameter and then pressing
Totalizer has a maximum value of 99 999 999. If this number is reached, the totalizer
must be reset to zero to continue tracking this value.
Parameter
Flow rate
Displays the current flow rate.
Peak flow
Displays maximum flow rate of water since last reset. By entering the
parameter, date and time of occurrence will be displayed.
Totalizer
Displays total volume of water used since last reset.
Last Regen
Displays time occurred after last regeneration.
Reserve (only
Displays the reserve volume based on the reserve type selected under master
available for
settings
softener meter
delayed
regeneration type)
Software Version Displays the software version installed on the controller.
No. of Regens
Displays how many manually and system-initiated regenerations the system
has gone through since last reset.
60 / 108
Diagnostics
flow rate
peak flow
totalizer
to return to the home screen.
.
5.7
Lpm
9.2
Lpm
153
L
Description
Ref. MKT-IM-038 / E - 22.10.2021