Pentair FOLEO 5800 XTR Installer Manual page 90

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Installer manual Foleo 5800 XTR - Maintenance
8.5.7.8
Disassembling/assembling valve from/on tank
1. Remove the softener cover, see First steps [
[
Page 75].
2. Release the tube
3. Remove the DLFC clip
4. Unscrew
(3)
and remove the meter (6).
5. Unscrew, counter-clockwise, the valve
6. Perform maintenance or change the valve (7).
7. Lubricate the valve tank adapter and riser tube o-rings with approved P-80
lubricant only.
CAUTION
Using another type of lubricant, such as petroleum-based lubricants (Vaseline, oils, or
hydro-carbon-based lubricants) or silicone grease, may damage the valve.
8. Spin the valve (7) onto the tank (8), ensuring the threads are not cross-threaded.
9. Rotate the valve (7) clockwise and freely, without using force until it comes to a stop.
Info
This stop position is considered point zero.
10. Rotate the valve (7) clockwise from point zero to between ¼ turn and ½ turn.
CAUTION
Do NOT exceed 27 Nm of torque when installing the valve.
Exceeding this limit may damage the threads and cause failure.
11. Reverse steps 1. to 4. to rebuild.
90 / 108
(1)
from push-fit fitting (2).
(5)
and extract the DLFC assembly and elbow (4).
Page 74] and Softener cover removal
(7)
from tank (8).
®
Emulsion
Ref. MKT-IM-038 / E - 22.10.2021