Installer manual Foleo 5800 XTR - Programming
Screen name Parameters
Valve
System
Valve
Regen type
Media
volume
Salt dosage
BLFC size
Capacity
Hardness
Calendar
override
regeneration
Regeneration
time
Reserve
Regeneration Regeneration
flow
Relay output
Aux.1/Aux.2
Meter
Meter type
Emergency
regeneration
Continuous
flow detect
42 / 108
Values
4
5800
Softener delayed
10, 15, 20 or 28 L
100 or 150 g/L
0.500 gpm
g/L CaCO
3
or
3
°Hm
Off - 1 - 99 days
HH:MM
Variable reserve
Variable refill/brining
Off
0.75" turbine
Off
On
Notes
Type 4 (single system) is currently the only
available selection.
Regeneration type is described in detail on
Variable Refill/Brining regeneration cycle
(5-cycles operation) [
Respectively for Foleo 10, Foleo 15, Foleo
20 and Foleo 30.
Depending on inlet hardness.
Only required on softener metered
systems to calculate treated water
capacity and reserve.
Represents total system capacity between
regenerations.
Calculates treated water capacity and
reserve. Represents hardness of
untreated water.
Report to local regulation.
Set at a time of no or low water usage.
Only available when softener meter
delayed regeneration type is selected.
Selecting fixed % or fixed volume will
display additional configuration options.
Variable reserve is calculated based on
previous day's water usage.
Cycle steps on the home screen and
during regeneration will change to reflect
the cycle steps and order.
Variable refill/brining calculates refill
time based on salt dosage, media volume,
and BLFC Size, and it is not possible to
change it.
Gives an alarm if continuous flow is
detected at the outlet.
Ref. MKT-IM-038 / E - 22.10.2021