Installer manual Foleo 5800 XTR - Maintenance
8.5.7.3
BLFC cleaning
1. Remove the softener cover, see First steps [
[
Page 75].
2. Disconnect the tube
3. Unscrew the BLFC holder
4. Using pliers, remove the grid
5. Remove the BLFC
6. Clean or change the BLFC (11).
7. Lubricate the seal
Caution - material
Using another type of lubricant, such as petroleum-based lubricants (Vaseline, oils, or
hydro-carbon-based lubricants) or silicone grease, may damage the valve.
8. Reverse above procedure steps to rebuild.
84 / 108
(14)
(push fit system (13)).
(12)
from chlorine generator (8).
(10)
from BLFC holder (12).
(11)
from the grid (10).
(9)
with approved P-80
Page 74] and Softener cover removal
®
Emulsion lubricant only.