OPERATION AND FUNCTIONS OF THE SUPER USER CODE

1) Operate Output 1 and 2
The operation of the Super User Code is just like a normal User Code. Simply key-in the Code with a
specific output number for the desired Output. The Super User Code can also be used to reset an
operating output timer instantly.
SUPER USER CODE
---------- Output 1 Activates or Resets
SUPER USER CODE
---------- Output 2 Activates or Resets
Optional Functions Controlled by Super User Code for Output 1
Apart from controlling of the three outputs 1 and 2; the Super User Code can also be used to enable
the optional functions controlling Output 1 for user convenience or security enhancement.
Super User Code and Egress Button are excluded from any system inhibition and lockup functions;
they are valid for door open at anytime for safety.
2) Override The Door Lock Controlled by Output 1 (Keep Door Un-locked)
The Output 1 is usually for door lock control. In some situations, the door may require un-locked for
a period of time to allow door opening without User Code or EM Card for entry / exit convenience.
This function Starts / Stops in toggle with the following code entry.
---------- The Door is Un-locked, Start / Stop in Toggle
SUPER USER CODE
NOTE :
The door is un-locked while the function is enabled. The "Output 1" LED (Green) turns ON.
Do not forget to stop this function after use because the door is un-locked. Also, the system
refuses the optional functions (3) & (4) while Override function comes into effect.
This feature is good for all the "Fail-safe electric locks".
"Fail-secure electric lock" requires power to keep in un-locked condition. It takes high current
all the time while the function comes into effect and may cause damage to it. This function is not
recommended for Fail-secure electric lock.