Visitor Codes (For Output 1 Only) - AEI DK-2822 User Manual

Rfid access control keypad
Table of Contents

Advertisement

VISITOR CODES (FOR OUTPUT 1 ONLY)

The Visitor Codes are temporary user codes for Output 1 (mainly for door strike in access control).
They can be programmed as "One Time Codes" or "Codes with Time Limit". The Visitor Codes
will be cleared automatically after use if they are one time codes, or, when the allowed time
expires.
LOCATION
VISITOR ID
VALID PERIOD




-
(1)
(2)
(1) LOCATION

Key in Location
(2) VISITOR ID
-
--- 50 Visitor IDs for the 50 visitor codes. They are Two-digit numbers
---
Clear all the Visitor Codes in Location 40. Please see the Programming example
below for the details.
(3) VALID PERIOD
The codes in this box MUST be two digits and they represent the time of operation.
--- One Time Code
One Time Code has no time limit but it can only be used for ONCE. It is cleared by the
system automatically after use.
-
--- Time Limit in Hour(s)
The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with
a two-digit number of 01 to 99. The visitor code is cleared by the system when
the time limit reaches.
(4) VISITOR CODES
The Visitor Codes can be 4-8 digits for Manual Mode code entry.
The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code
entry.
The Visitor Codes can not reset Duress Output.
When a new Visitor Code is put in the same Code box, the old code is replaced.
NOTE: All Visitor Codes will be cleared after power down to prevent extension/confusion of
their valid time limit.
(5) VALIDATION
Press
key once. Two-beep confirms the entry.
VISITOR CODE


or
-
4-8 DIGITS
(3)
(4)
26
(Location 40)
VALIDATION
(5)