EGRESS DELAY , WARNING AND ALARM

LOCATION
CONFIGURATIONS



-
(1)
(2)
(1) LOCATION

Key in Location
(2) CONFIGURATIONS OF THE EGRESS WARNING AND ALARM
Key in the number to enable 1 of the 6 configurations described below:

--- Momentary Contact Mode without Warning -- (Default)
Press the Button once. No warning or alarm is given during Egress Delay.
Good for silent area. The people have to wait for the door open until the delay time reaches.

--- Momentary Contact Mode with Warning Beep
Press the Button once. The system gives Warning Beeps during the Egress Delay.
Good for the place required attention. The keypad beeps during the people are waiting for the
door open.

--- Momentary Contact Mode with Warning Beep & Alarm
Press the Button once. The system gives Warning Beeps and also activates its Alarm O/P during
the Egress Delay
Good for door for the authorized people only. The keypad beeps and report alarm to a security
system during the people are waiting for the door open.
This is usually an "Emergency Exit". The door can be opened with the Keypad without triggering
of the Buzzer and Alarm Output.

--- Holding Contact Mode without Warning
Press and hold the Button. No warning or alarm is given during the Egress Delay.
Good for the silent area. The people require to press & hold the button until the delay time
reaches for the door open.

--- Holding Contact Mode with Warning Beep
Press and hold the Button. The system gives Warning Beeps during Egress Delay.
Good for the place required attention. The keypad beeps while the button is kept pressed during
the people are waiting for the door open.

--- Holding Contact Mode with Warning Beep & Alarm
Press and hold the Button. The system gives Warning Beeps and also activates its Alarm O/P
during Egress Delay.
This is usually an "Emergency Exit". The door can be opened with the Keypad without triggering
of the Warning and Alarm.
(3) EGRESS DELAY TIMER

--- No Delay – (Default)
Output 1 activates instantly (the door is released instantly) when the Egress Button is pressed.


--- Egress Delay Timing
Put a number of 1 to 99 into the box to enable the Egress Delay. The number is the time in
second, which starts to count when the Egress Button is pressed. Output 1 activates (the door is
released) when the delay time reaches.
(Location 90)
DELAY TIME
VALIDATION



or
-
(3)
(4)