Multi-User Mode Operation - AEI DK-9680 Series Manual

Split-decoded security keypad three-output system with door alarm
Table of Contents

Advertisement

The
is the
c)
Accelerated Code
First Two Digits
programmed in Start/Stop mode with Accelerated Code, it is possible to
Output 1, 2 or 3 with only the First Two Digits of the User Code. Deactivating of the corresponding
Output 1, 2 or 3 always requires the composition of its own Complete User Code.
In this example, Output 3 has been programmed in Start / Stop Mode with Accelerated Code.
The Complete Code of Code 3:
9270
92 #
----------------- Output 3 starts
9270
---------------- Output 3 stops
d)
Try to put some random false codes to the keypad to test its
one code and it generates 5 beeps for each unsuccessful code entry. The keypad locks itself during 15
minutes after 10 successive false codes are entered. Normal operation will be resumed after 15 minutes
expired, or, it can be reset with the Master Code during the locking period.
3289 #
----------- Locking is reset and keypad resumes normal operation
e)
In this example, the keypad has been programmed with
the door that is equipped with
Door Sensing Switch
The alarm will activate instantly for 60 seconds. The alarm can be stopped by User Code 1 before the
end of the alarm time.
8321
----------------- Alarm stops
NOTE:
The testing may not be feasible if the door is locked. It is necessary to un-lock the door with the
mechanical key before testing.
f)
The
Door Open-Too-Long Alarm
has been enabled in programming. Try to command Output 1 with
or the
. Open the door that is equipped with
1
Egress Button
more than 60 seconds (the programmed time). The alarm starts. Close the door, the alarm stops
automatically. This feature reminds the owner to close the door in case it is stuck.
g)
The keypad incorporates
Door Chime
B) MULTI-USER MODE OPERATION -- An Example
1) Re uirement
q
-- Set the following data into the system:
a) Multi-User Mode Operation
b) Change the factory-set Master Code 0000 to a Personal Master Code 3289
c) Set 1st User Code of Group 1 in 8321
d) Set 2nd User Code of Group 1 in 11223
e) Set 3rd User Code of Group 1 in 33221
f ) Set 1st User Code of Group 2 in 6854
g) Set 2nd User Code of Group 2 in 54321
h) Set 1st User Code of Group 3 in 9270
i ) Set 2nd User Code of Group 3 in 22898
j ) Set Output 1 in Momentary Mode, 1 second
k) Set Output 2 in Start / Stop Mode without accelerated code
l ) Set Output 3 in Start / Stop Mode with accelerated code
m) Set the keypad to lock itself during 15 minutes after 10 successive false codes
n) Set the keypad with door Forced-Open-Alarm enabled
o) Set the allowable time for door left open for 60 seconds before triggering of the door Open-Too-Long
alarm
of the User Code. If the User Code 1, 2 or 3 has been
activate
The Accelerated Code of Code 3:
92
Safety
. The keypad considers 4 digits as
Door Forced-Open-Alarm
enabled. Try to open
, without the use of
Code 1
or the
, and leave it open for
Door Sensing Switch
. To activate the door chime, just simply press the
9
2) Programming
the corresponding
0000 *
8901 #
0 3289 #
1 01 8321 #
1 02 11223 #
1 03 33221 #
2 1 6854 #
2 2 54321 #
3 1 9270 #
Egress Button
.
3 2 22898 #
40 1 #
51 #
62 #
72 10 #
Code
81 #
9 60 #
BELL
key.
*
------------------------------------ Keypad exits programming mode. All the data above are saved and ready
NOTE:
3) Operate The Keypad
a)
To command the output 1, enter any one of the User Codes in Group 1 into the keypad and validate via
the
8321 #
11223 #
33221 #
b)
To command the output 2, enter any one of the User Codes in Group 2 into the keypad and validate via
the
6854 #
54321 #
-- Set the above requirement into the keypad:
-------------------------- Enter to programming mode with the factory-set Master Code
------------------------- System has been set for Multi User Mode**
-------------------- 3289 has been saved as the new Personal Master Code
Code
--------------- 8321 has been saved as the 1st User Code of Group 1 with Duress
Alarm OFF Code functions
------------- 11223 has been saved as the 2nd User Code of Group 1 with Duress
Alarm OFF Code functions
------------- 33221 has been saved as the 3rd User Code of Group 1 with Duress
Alarm OFF Code functions
----------------- 6854 has been saved as the 1st User Code of Group 2
--------------- 54321 has been saved as the 2nd User Code of Group 2
----------------- 9270 has been saved as the 1st User Code of Group 3
--------------- 22898 has been saved as the 2nd User Code of Group 3
------------------------- Output 1 has been set in Momentary Mode, 1 second
----------------------------- Output 2 has been set in Start / Stop Mode without accelerated code
----------------------------- Output 3 has been set in Start / Stop Mode with accelerated code
----------------------- The keypad has been set to lock during 15 minutes after 10 successive
false codes
----------------------------- The keypad has been set with door Forced-Open-Alarm enabled
------------------------- The keypad has been set with 60 seconds allowable time for door left
open
for use
a) **Enter the Multi User Mode Command Code "8901" may not be necessary if the keypad was
already in Multi User Mode.
b) In case of wrong entry during programming, cancel it with
enter.
-- Taking the data programmed above as reference
#
key
------------ Output 1 activates for 1 second
---------- Output 1 activates for 1 second
---------- Output 1 activates for 1 second
#
key
------------ Output 2 starts (or stops)
---------- Output 2 starts (or stops)
10
&
Super User
&
&
&
#
key, or, wait 10 seconds, then re-