Auxiliary Information - AEI DK-2822 User Manual

Rfid access control keypad
Table of Contents

Advertisement

AUXILIARY INFORMATION

DRY CONTACT
A dry contact means that no electricity is connected to it. It is prepared for free connections. The
Relay Output contacts provided in this keypad system are dry contacts.
N.C.
Normally Closed, the contact is closed circuit at normal status. It is open circuit when active.
N.O.
Normally Open, the contact is open circuit at normal status. It is closed circuit when active.
TRANSISTOR OPEN COLLECTOR OUTPUT
An open collector output is equivalent to a Normally Open (N.O.) contact referring to ground
similar to a relay contact referring to ground. The transistor is normally OFF, and its output
switches to ground (-) when active. The open collector can only provide switching function for
small power but it is usually good enough for controlling of an alarm system. The Duress,
Inter-lock and Key Active/Alarm Outputs of the keypad are open collector outputs.
OPEN COLLECTOR
OUTPUT ----
EQUIVALENT
Output switches to
ground when activated
N.O. CONTACT
OUTPUT ----
Output switches to
ground when activated
68