AEI DK-2891A User Manual

AEI DK-2891A User Manual

Vandal resistant back-lit weatherproof rfid access control keypad
Table of Contents

Advertisement

Quick Links

VANDAL RESISTANT
BACK-LIT WEATHERPROOF
RFID ACCESS CONTROL KEYPAD
DK-2891A
DK-2891B
DK-2891
User Manual (MK-II)
FOR ELECTRIC LOCK
AND SECURITY SYSTEMS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DK-2891A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AEI DK-2891A

  • Page 1 VANDAL RESISTANT BACK-LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD DK-2891A DK-2891B DK-2891 User Manual (MK-II) FOR ELECTRIC LOCK AND SECURITY SYSTEMS...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ······································································································································· 4 FEATURES ················································································································································ 4 OPTIONAL DEVICES FOR SYSTEM EXPANSION ·················································································· 5 SPECIFICATIONS ···································································································································· 6 INSTALLATION ········································································································································· 7 Precautions ············································································································································ 7 CONNECTION TERMINALS AND INDICATORS ·················································································· 8-9 The On-Board LED Indicators ·················································································································· 9 Pacifier Tone & The LED Signals ··············································································································...
  • Page 4 Operation Modes ···································································································································· 36 Close The Programming Mode ················································································································ 36 PROGRAMMING MAKE SIMPLE - For General Users ····································································· 37-38 PROGRAMMING SUMMARY CHART ································································································ 39-40 ···················································································································· 41 APPLICATION EXAMPLES Stand Alone Door Lock ························································································································ 41 Basic Wirings of a Stand Alone Lock ·····································································································...
  • Page 5: Introduction

    The Version B comes with Output 1 for door strike and Output 2 for door bell activation. DK-2891A – Output Relay 1 & 2 Controlled by User Codes / Cards DK-2891B – Output Relay 1 Controlled by User Codes / Cards; Output 2 by Bell Button FEATURES A member of the Tri-Tech series keypads compatible with the optional controllers &...
  • Page 6: Optional Devices For System Expansion

    OPTIONAL DEVICES FOR SYSTEM EXPANSION The Optional Decoders Available for Split-decoded Operation DA-2800 – Full Feature Decoder with RF Remote Control DA-2801 – Full Feature Decoder The Auxiliary Reader / Keypad Available for Multi-station Operation AR-2802S or A – EM Card Reader AR-2806S or A –...
  • Page 7: Specifications

    SPECIFICATIONS ● Operating Voltage: ● 12V DC Nominal; 11-15V DC ● Operating Current: .60mA (quiescent) to 100mA ● Operation Temperature: .-20°C to +70°C ● Environmental Humidity: .5-95% relative humidity non-condensing ● Working Environment & Ingress Protection: .Indoor or Outdoor, IP-65 Weatherproof ●...
  • Page 8: Installation

    INSTALLATION ASSEMBLY GREEN: DUAL LED DOOR AMBER: MAINS RED: INHIBIT VERSION A  CARD VERSION B READER Back Cover Front Cover PRECAUTIONS 1) Prevent Interference: The EM Card reader is working at the frequency of 125Khz. Installation precautions are necessary. Make sure the location for installation has no strong low frequency electro-magnetic wave.
  • Page 9: Connection Terminals And Indicators

    A relay output dry contact with maximum rating of 24 VDC/1Amp which is selectable for N.C. (Normally Closed) or N.O. (Normally Open) output via jumper. DK-2891A - Output contact controlled by the PINS and/or cards in group 2 DK-2891B - Output contact controlled by the Bell Button SELECTION JUMPER FOR OUTPUT 2 N.O.
  • Page 10: The On-Board Led Indicators

    7 : EG IN (Egress Input) A Normally Open (N.O.) input terminal referring to (-) ground. With the help of connecting a normally opened button to activate the Output 1 for electric door lock strike in the same manner of using the Group 1 User PINs or Cards.
  • Page 11: Preparation For Programming

    PREPARATION FOR PROGRAMMING A) CRITERIA FOR CODES AND CARDS 1) Prime Codes The prime codes include the a) User Codes, b) Master Code, c) Duress Codes, d) Super User Codes, e) Common User Codes and f) Visitor Codes. All these codes MUST be unique. It is not allowed to repeat a prime code for second function.
  • Page 12: C) List Of User Information

    5) EM Card + Proprietary Secondary User Code – Operation Media 3 The keypad accepts programming with each card having its own proprietary user code to work. It prevents any other people can use the lost card to open the door. Card with proprietary user code approach is ideal for the area that high security is the main concern.
  • Page 13: Programming And Operation

    PROGRAMMING & OPERATION POWER-UP THE KEYPAD The keypad gives power-up delay of 1 minute after power has been applied. It is the time frame designed for setting the keypad to programming mode with DAP code. See the details of “DAP CODE –...
  • Page 14: Direct Access To Programming Mode With The "Dap" Code - 2 8 2 8

    DIRECT ACCESS TO PROGRAMMING MODE WITH “DAP” CODE -- 2 8 2 8 In case the Master Code is forgotten, apply the following procedures precisely to set keypad into programming mode with DAP code: Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged. Switch ON power again.
  • Page 15: The Default Values After Refreshing

    Nil ----- User Program Required Common User Code 1 Nil ----- User Program Required Common User Code 2 Nil ----- User Program Required (DK-2891A only) User Codes & Cards for O/P 1 Nil ----- User Program Required User Codes & Cards for O/P 2...
  • Page 16: Master Code

    MASTER CODE (Location 01) LOCATION MASTER CODE VALIDATION   4 to 8 Digits (1) LOCATION  Key in Location (2) MASTER CODE Master Code is the authorization code for setting the system to programming mode. It is NOT an User Code operating the output relays. The Master Code can be 4 to 8 digits.
  • Page 17: Operation And Functions Of The Super User Code

    OPERATION AND FUNCTIONS OF THE SUPER USER CODE 1) Operate Output 1 and 2 The operation of the Super User Code is just like a normal User Code. Simply key-in the Code with a specific output number for the desired Output. The Super User Code can also be used to reset an operating output timer instantly.
  • Page 18 4) Inhibit All The User Codes & EM Cards for Output 1 (Disable Access Control Manually) To enhance the security of the access control keypad, the owner can stop the keypad after office hour or while the house is nobody inside. Once the Output 1 (for door lock control) is inhibited, all the User Codes / Cards for it become invalid and those people holding the User Code or Card are refused.
  • Page 19: Common User Codes For Output 1 & 2

     (1) LOCATIONS -- Location Stores The Common User Code for Output 1 -- Location Stores The Common User Code for Output 2 (DK-2891A only) (2) COMMON USER CODES The Common User Code can be 4 to 8 digits. When a new Common User Code is keyed in and confirmed, the old one is replaced.
  • Page 20: User Codes/Card For Output 1

    – Group 1 – 1,000 User Codes / Cards for controlling Output 1  – Group 2 – 100 User Codes / Cards for controlling Output 2 (DK-2891A only) (2) MEDIA (Operation Media)- please also see page for more information of their security level ...
  • Page 21: Examples - Programming And Operation

    EXAMPLES – PROGRAMMING AND OPERATION 1) Example 1 -- EM Card Only : i) Programming : Read Card (a) The card is programmed for operating Output 1 (b) The operation is medium EM Card only (c) Take ID number 001 in Group 1 to store the card, which is one of the IDs in 000-999 (d) Put the card close to the reader, one beep confirms the reading (e) Press # to store the “Card”, two-beep confirms a valid entry ii) Operation : (while the system is back to operation mode)
  • Page 22 3) Example 3 -- EM Card + Secondary User Code i) Programming : Read Card (a) The card is programmed for operating Output 1 (b) The operation medium is EM Card + Secondary User Code (c) Take the ID number 002 in Group 1 to store the Card & Code, which is one of the IDs in 000-999 (d) Put the card close to the reader.
  • Page 23 5) Example 5 -- Delete An User Code & / or EM Card (for O/P 1 or 2) : i) Delete An User Code or A Lost EM Card User ID (a) Key in the User Group that the User ID belongs to. “10” for Group 1 and “20” for Group 2 (b) Key in “5”...
  • Page 24: Visitor Codes (For Output 1 Only)

    VISITOR CODES (FOR OUTPUT 1 ONLY) (Location 40) The Visitor Codes are temporary user codes for Output 1 (mainly for door strike in access control). They can be programmed as “One Time Codes” or “Codes with Time Limit”. The Visitor Codes will be cleared automatically after use if they are one time codes, or, when the allowed time expires.
  • Page 25 EXAMPLES: Example 1: Set a “One Time Visitor Code” with the number of “1 2 6 8” for the Output 1 (a) Visitor Code Programming, (b) The Visitor ID, (c) An One Time Code, (d) The Visitor Code, (e) Entry Confirmation Example 2: Set a “Visitor Code”...
  • Page 26: Output Mode & Timing For Output 1 & 2

     (1) LOCATIONS -- Location for Output 1 -- Location for Output 2 (DK-2891A only) (2) OUTPUT MODE & TIMING Start /Stop Mode (Toggle) The number 0 sets the output to Start / Stop mode. The output Starts when an User Code and/or Card is entered/read;...
  • Page 27: System Real-Time-Clock

    SYSTEM REAL-TIME-CLOCK (Location 55) This 24 hour real-time-clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 (mainly for electric door lock strike). No real-time-clock setting is required if daily start-stop inhibition at Location 56 is not enabled.
  • Page 28: Start & Stop Times For Daily Inhibition Of Output 1

    START & STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 (Location 56) Setting with start and stop times into the keypad, the real-time inhibition period for output 1 will recycle daily until the time settings are cleared. This function works with the real-time-clock. Set up the real-time at Location 55 is necessary. For safety reason, the Egress Button is designed always valid.
  • Page 29 Programming and Operation Examples: (i) Set the starting and stopping time for the real-time inhibition period a) Set Inhibition Period from 12:30 PM (today) – 1:30 PM (same day) for lunch time:     b) Set Inhibition Period from 6:30 PM (today) – 8:15 AM (next day) for office close: ...
  • Page 30: Personal Safety And System Lock-Out

    PERSONAL SAFETY AND SYSTEM LOCK-UP (Location 60) LOCATION LOCK-UP OPTIONS VALIDATION   1 to 2 Digits (1) LOCATION  Key in Location (2) LOCK-UP OPTIONS The Options are represented by the following Numbers. They are described below:  --- After 10 successive false Card/User Code trials, the keypad locks during 60 seconds. - (Default) ...
  • Page 31: User Code Entry Mode - Auto Or Manual

    USER CODE ENTRY MODE – Auto or Manual (Location 70) LOCATION ENTRY MODES VALIDATION     (1) LOCATION  Key in Location (2) USER CODE ENTRY MODES Two modes 1 and 2 are available for User Code entry options. The EM Card is always in Auto Entry Mode and is not affected by the selection here.
  • Page 32: Output Operation Announcer

    OUTPUT OPERATION ANNOUNCER (Location 72) LOCATION FUNCTION MODES VALIDATION     (1) LOCATION  Key in Location (2) FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs. There are two notification modes available for the selection.The notification is also OFF while the Pacifier Tone OFF mode in the Location 71 is selected.
  • Page 33: Intelligent Egress Button - An Unique Feature Of A Contemporary Keypad

    INTELLIGENT EGRESS BUTTON – AN UNIQUE FEATURE OF THE KEYPAD INTRODUCTION Most of the keypads for access control are just for controlling “Going In” from outside. It is not enough for today’s access control systems. In fact, controlling “Going Out” is also very important in some public passage areas those are not allowed to use locks or digital keypads for stopping of “Going Out”...
  • Page 34 High Traffic Passage: A short buffer time may be necessary for opening a door outward after pressing the egress button for those exits open to a high traffic passage. An egress button with short delay and warning beeps helps the user to pay attention to the people passing by to prevent hitting them when the door is pushed outward.
  • Page 35: Egress Delay , Warning And Alarm

    EGRESS DELAY , WARNING AND ALARM (Location 90) LOCATION CONFIGURATIONS DELAY TIME VALIDATION          (1) LOCATION  Key in Location (2) CONFIGURATIONS OF THE EGRESS WARNING AND ALARM Key in the number to enable 1 of the 6 configurations described below: ...
  • Page 36 NOTE: 1) Momentary Contact -- The Egress Delay starts to count when the egress button is momentarily pressed. Output 1 activates automatically (door is released) when the delay time reaches. Holding Contact -- The user MUST hold the egress button in contact for the whole period of the Egress Delay time until Output 1 activates.
  • Page 37: Operation Modes

    OPERATION MODES (Location 94) The keypad is programmable for keypad mode to work stand-alone for door control directly or for server mode to work with a split-decoder for high security access control. LOCATION OPERATION MODES VALIDATION     (1) LOCATION ...
  • Page 38: Programming Make Simple - For General Users

    PROGRAMMING MAKE SIMPLE – For General Users The DK-2891 is a multi purpose keypad. It has many functions for user’s selection. For those general users taking the keypad for door strike only, most of the features can be kept in their Default values. Only the User Codes / Cards and a private Master Code are required to program.
  • Page 39 5) Record an “EM Card + User Code” to Operate The Output 1 for Door Open      READ CARD (a) 10 = Programming Location for Output 1 (b) 3 = Programming option for EM Card + User Code. (The User Code can be repeated use or proprietary) (c) 003 = One of the 1,000 User IDs for the User /Card from 000-999...
  • Page 40: Programming Summary Chart

    PROGRAMMING SUMMARY CHART ENTRY LIMITS & CODE FACTORY FUNCTION CODE ENTRY LOCATION DEFAULT OPTIONS   Master Code 4-8 Digits MASTER CODE   Super User Code 4-8 Digits SUPER USER CODE Common User Code for   COMMON USER CODE 1 O/P 1 4-8 Digits Common User Code for...
  • Page 41 FACTORY ENTRY LIMITS & CODE FUNCTION CODE ENTRY LOCATION DEFAULT OPTIONS CODE 1 - FUNCTION MODE: 1---Momentary, No warning 2---Momentary, with Mode = 1 warning Momentary, Egress Delay Warning & 4---Hold Contact, No   No warning CODE 1 CODE 2 Alarm warning TIME = 0...
  • Page 42: Application Examples

    APPLICATION EXAMPLES STAND ALONE DOOR LOCK ELECTRIC LOCK DK-2891 NOTE: Connect the 1N4004 as close as possible to the lock in parallel with the lock power terminals of the lock to absorb the back EMF to prevent it from damaging the keypad. The 1N4004 is not required if the electric lock is AC operated.
  • Page 43: Application Expansions

    APPLICATION EXPANSIONS Apart from standard-alone operation, DK-2891 is expandable to be a Multi-station System or a High Security Multi-station Split-decoded System with its Data I/O Bus for the connection of the optional auxiliary keypad(s) and decoder. The wiring is very simple. Just connect all the related devices in parallel with the Data I/O Bus.
  • Page 44: The Split-Decoders

    The Split-decoders (Optional) DA-2800 DA-2801 Decoder with RF Remote Control Standard Decoder Connection Terminal OUTPUT 1 OUTPUT 2 OUTPUT 3 ...
  • Page 45: Dual-Station Access Control Door Lock

    1) Dual-station Access Control Door Lock Description Owner can select an auxiliary reader AR-2802 or an auxiliary reader-keypad AR-2806, AR-2807 or AR-2809 and connect it with the master keypad DK-2891 to expand the system with dual-station for user convenience. Simply connect the reader or the reader-keypad in parallel with the Data I/O Bus of the master keypad.
  • Page 46: Multi-Station Access Control Door Lock

    2) Multi-station Access Control Door Lock Description This is an expansion of application (1). The DK-2891 is expandable to a multi-station system for user convenience with the auxiliary readers AR-2802 and/or the auxiliary reader-keypads AR-2806, AR-2807 &r AR-2809. Total 3 auxiliary readers or reader-keypads can be connected in parallel with the Data I/O Bus and they provide the same functions like the master keypad in using cards and user codes.
  • Page 47: Split-Decoded Access Control Door Lock

    3) Split-decoded Access Control Door Lock Description Apart from stand-alone operation, the DK-2891 can be up-graded to high security Split-decoded operation with a decoder unit DA-2800 or DA-2801. The decoder is inside the house with all the input and output installations connecting to it. The DK-2891 manages the data in the system with its Data I/O Bus.
  • Page 48: Split-Decoded Multi-Station Access Control Door Lock

    4) Split-decoded Multi-station Access Control Door Lock Description This is an expansion of application (3). The DK-2891 is expandable to a multi-station system in Split-decoded operation. It is compatible with the auxiliary readers AR-2802 and the auxiliary reader-keypads AR-2806, AR-2807 & AR-2809. Total 3 auxiliary readers or reader-keypads can be connected in parallel with the Data I/O Bus.
  • Page 49: Application Hints For The Auxiliary Terminals

    1. GREY series with a 24 hour N.C. protection zone of an 2. PINK alarm system if required. (B) OUTPUT 2 (DK-2891A ONLY) ( i ) Shunting an N.C. Zone 3. PURPLE 4. ORANGE Put Output 2 jumper to N.O.
  • Page 50 (C) OUTPUT 2 -- Door Bell Button (DK-2891B ONLY) (OPTIONAL) The output 2 of the DK-2891B is prepared for ELECTRONIC 3. PURPLE triggering a low power door chime. DO NOT DOOR CHIME use it as a high voltage power path for a door 4.
  • Page 51: Auxiliary Information

    AUXILIARY INFORMATION DRY CONTACT A dry contact means that no electricity is connected to it. It is prepared for free connections. The Relay Output contacts provided in this keypad system are dry contacts. N.C. Normally Closed, the contact is closed circuit at normal status. It is open circuit when active. N.O.
  • Page 52 AEI PROTECT-ON SYSTEMS LIMITED www.apo-hk.com ...

This manual is also suitable for:

Dk-2891b