Ecode
Detail
Item
Code
E719
0002
Title
Erroneous communication with Coin Vendor (serial
communication)
Description
-
Remedy
-
E736
0000
Title
Erroneous communication between CCU and controller.
Description
-
Remedy
-
E744
0001
Title
Mismatched version between the language file and the
Bootable
Description
-
Remedy
-
E744
0002
Title
Oversized language file in HDD
Description
-
Remedy
-
E744
0003
Title
Mismatched version between the language file and the
Bootable
Description
-
Remedy
-
E744
0004
Title
Language file reading error
Description
-
Remedy
-
E804
0000
Title
Failure of the Power Supply Cooloing Fan (FAN6)
Description
When lock signal is detected for 5 sec while the Power
Supply Cooloing Fan (FAN6) is stopped.
* The same condition is detected after the error retry is
performed.
Remedy
1.Disconnect and then connect the connector (J205) on the
DC Controller PCB (PCB4).
2.Replace the Power Supply Cooloing Fan (FAN6).
3.Replace the DC Controller PCB (PCB4).
E804
0001
Title
Unstable rotation of the Power Supply Cooloing Fan (FAN6)
Description
When lock signal failed to be detected for 5 sec while the
Power Supply Cooloing Fan (FAN6) is driven.
* The same condition is detected after the error retry is
performed.
Remedy
1.Disconnect and then connect the connector (J205) on the
DC Controller PCB (PCB4).
2.Replace the Power Supply Cooloing Fan (FAN6).
3.Replace the DC Controller PCB (PCB4).
7
Description
7
Ecode
Detail
Item
Code
E805
0000
Title
Failure of the Exhaust Fan (Rear) (FAN3)
Description
"When lock signal is detected for 5 sec while the Exhaust Fan
(Rear) (FAN3) is stopped.
* The same condition is detected after the error retry is
performed."
Remedy
1.Disconnect and then connect the connector (J206) on the
DC Controller PCB (PCB4).
2.Replace the Exhaust Fan (Rear) (FAN3).
3.Replace the DC Controller PCB (PCB4).
E805
0001
Title
Unstable rotation of the Exhaust Fan (Rear) (FAN3) or
Finisher Fan 1 (M8) or Finisher Fan 2 (M9)
Description
1.When lock signal failed to be detected for 5 sec while the
Exhaust Fan (Rear) (FAN3) is driven.
2.When lock signal failed to be detected for 5 sec while the
Finisher Fan 1 (M8) is driven.
3.When lock signal failed to be detected for 5 sec while the
Finisher Fan 2 (M9) is driven.
* The same condition is detected after the error retry is
performed.
Remedy
1.Disconnect and then connect the connector (J206) on the
DC Controller PCB (PCB4).
2.Replace the Exhaust Fan (Rear) (FAN3).
3.Replace the Finisher Fan 1 (M8).
4.Replace the Finisher Fan 2 (M9).
5.Replace the DC Controller PCB (PCB4).
E805
0002
Title
Failure of the Exhaust Fan (Front) (FAN4)
Description
When lock signal is detected for 5 sec while the Exhaust Fan
(Front) (FAN4) is stopped.
* The same condition is detected after the error retry is
performed.
Remedy
1.Disconnect and then connect the connector (J206) on the
DC Controller PCB (PCB4).
2.Replace the Exhaust Fan (Front) (FAN4).
3.Replace the DC Controller PCB (PCB4).
E805
0003
Title
Unstable rotation of the Exhaust Fan (Front) (FAN4)
Description
When lock signal failed to be detected for 5 sec while the
Exhaust Fan (Front) (FAN4) is driven.
* The same condition is detected after the error retry is
performed.
Remedy
1.Disconnect and then connect the connector (J206) on the
DC Controller PCB (PCB4).
2.Replace the Exhaust Fan (Front) (FAN4).
3.Replace the DC Controller PCB (PCB4).
7-8