4. Hardware Setup
DVI-D Interface Connection
Connect the DVI-D input on this unit to the DVI-D connector on the host computer or the PanelLink
connector. You can use a CONTEC IPC series or SBC (single board computer) as the host computer. In
this case, settings are required on each host computer.
Set the LCD type as follows depending on the host computer to be used.
When connecting to a IPC-BX/M630(PCI) series
No specific host settings are required if using this box computer. However, if using the Windows XP
operating system, only connect the analog RGB cable during installation. Change to the DVI connection
after installation completes.
When connecting to a IPC-BX/M360(PCI)C Series
Set the size of the connecting display by selecting "Advanced Chipset Features Setup" – "Panel Type" in
the BIOS setting section.
Example) For FPD-L7xST-DC1 : "800 x 600"
CAUTION
-
If connecting this display to a product with the "AUTO Select" function such as
IPC-BX/M360(PCI)C etc., or to a product with the "plug and play" function such as the
IPC-BX/M630(PCI) series, first connect cables, then turn on the display, always before turning on
the host computer. If the host computer is started before the display, it may not be able to read the
information on the display, and as a result, no screen image may come up.
In this case (e.g. when the display is turned on afterward, when a cable is connected afterward),
specify the display size in the BIOS settings on the host computer.
-
Do not connect these products with the LVDS at the same time. When doing so may cause an
abnormal display in the screen.
-
Connecting FPD-M75VT-DC1 and IPC-BX950TxD is not supported.