Instructions For Installing The Sfu Ont; Figure 6. Typical Ont Installation - ADTRAN Total Access 362R Installation And Maintenance Manual

Single family unit with rf return
Hide thumbs Also See for Total Access 362R:
Table of Contents

Advertisement

Instructions for Installing the SFU ONT

A typical ONT installation with UPS is shown in Figure 6.
Customer provided premises
wiring including CAT5 or
higher Ethernet cable and
POTS twisted pair to be
terminated in the ONT by
technician
Riser conduit for
fiber drop cable
6 AWG ground wire
installed from the ONT
to the established MGN
Installations may vary from this diagram depending on the manner in which the Customer 
Premises Equipment (CPE) wiring is installed, the location of the AC outlet used to power the 
ONT local power supply, whether or not a communications distribution panel was provided, 
and the proximity of the external ends of the CPE wiring to the subscriber's electrical service 
point.
61187715G1-5B
Communications
Distribution
Panel

Figure 6. Typical ONT Installation

Installation
UPS with battery backup
installed by technician
GFI/non-GFI outlet - highly
recommend non-GFI outlet
PVC conduit supplied by subscriber
with pull string for UPS low voltage
wiring installed by technician
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

1187715g1

Table of Contents