CAUTION
Wiring the UPS incorrectly can cause damage to the unit. Use caution when
connecting the wiring.
9. Plug the UPS power cord into the utility power cord inlet on the UPS.
10. Plug the UPS power cord into the wall outlet. (The UPS battery charges when it is 
11. Verify indicator lights are in agreement with manufacturer specifications and the unit is 
61187715G1-5B
Pin-Out
Power/Alarm
1
2
3
4
5
6
7
connected to the utility power. The battery charges fully during the first 18 hours of 
normal operation. Do not expect full battery run capability during this initial charge 
period.) 
functioning.

Table 5. UPS Pin-Out Connection

Description
LOW BAT
BAT MIS
REP BAT
ON BAT
SIG RTN
12 V RTN
+12 VDC
Pin-Out
UPS
7
6
5
4
3
2
1
Installation
31