Instructions For Installing The Mdu Ont; Figure 2-1. Typical Ont Installation - ADTRAN Total Access 374 Installation And Maintenance Manual

4-pots, 4-gige mdu ont
Hide thumbs Also See for Total Access 374:
Table of Contents

Advertisement

Total Access 374 4-POTS, 4-GigE MDU ONT Installation and Maintenance Guide

Instructions for Installing the MDU ONT

A typical exterior ONT installation with UPS is shown in
Installations may vary from this diagram depending on the manner in which the Customer
Provided Equipment (CPE) wiring is installed, the location of the AC outlet used to power the
ONT local power supply, whether or not a communications distribution panel was provided,
and the proximity of the external ends of the CPE wiring to the subscriber electrical service
point.
2-4
Customer provided premises
wiring including CAT5 or higher
Ethernet cable and POTS
twisted pairs to be Terminated
in the ONT by technician
ONT
Riser conduit for
fiber drop cable
Minimum 6 AWG ground
wire installed from the ONT
to the established MGN
Communications
Distribution
Panel
Power and Alarm leads
require a jacketed, 4 pair
wire of the proper gauge.
Wire run via Customer
provided PVC conduit or
per local practice.

Figure 2-1. Typical ONT Installation

Figure
2-1.
UPS with battery backup
installed by technician
GFI/non-GFI outlet - highly
recommend non-GFI outlet
PVC conduit supplied by subscriber
with pull string for UPS low voltage
wiring installed by technician.
61287703G1-5B

Advertisement

Table of Contents
loading

Table of Contents