8.2.1 Power Input (Required)

Power input is required and connects to the aircraft's power bus.
Input range is compatible with both 12V and 24V aircraft. Internally,
this power is diode OR'ed with the internal battery via a processor-
controlled switch. This architecture allows the unit to continue
operation if external power fluctuates or is completely lost.
Each AV-30-C must have a dedicated, properly labeled, pilot
resettable circuit breaker as part of the installation. Power for the
unit may be supplied from either the avionics bus or the main battery
master relay.

8.2.2 Pitot and Static Interfaces (Required/Optional)

In addition to directly displayable data such as airspeed and altitude,
pitot and static inputs are utilized within the probeless Angle of
Attack algorithm and provide the underlying source for various air-
data type data overlays (TAS & DALT).
When installed as a DG, pitot and static connections are not required
unless TAS and DALT are desirable (also requires a dedicated OAT
probe). See the detailed wiring diagram for more information.

8.2.3 Outside Air Temp Input (Optional)

The optional outside air temperature interface requires a dedicated
external analog probe. This port connection is compatible with the
Davtron P/N C307PS (not supplied).
This is a differential two-wire current source based on the Analog
Devices AD590KH component and supplies a current that
corresponds to the ambient temperature.
The sensor reading must be trimmed during the installation process
to compensate for probe-to-probe variations.
UAV-1003947-001, AV-30-C, Installation Manual
If two displays are connected to the same probe, the current
will be split between the two and incorrect readings will be
shown by both.