Removing and dismantling the valve assembly
Before continuing, the following parts
need to be removed as previously shown:
cleanerhead and yoke, (pages 6-7)
ball and motor bucket, (pages 20-21)
146
Undo the screw with the washer and
remove the static cover.
147
Remove the screw and washer in the
spring mount assembly.
148
Carefully unhook the front spring from the
peg on the valve assembly.
33
149
Pull the front face of the moving cover off the
retaining peg on the rear of the valve assembly.
150
Remove the rear of the moving cover and
the rear spring off the retaining peg.
151
Lift the spring mount assembly off the side
of the valve assembly.