PaloAlto Networks PA-7000 Series Hardware Reference Manual page 173

Hide thumbs Also See for PA-7000 Series:
Table of Contents

Advertisement

Service the PA-7000 Series Firewall Hardware
STEP 6 | (Same model replacement drive
the other drive in the RAID 1 array:
1. Pull the AMC handle on the replacement drive outward unl it stops to prepare it for
installaon into the LPC.
2. Install the replacement drive by gently sliding it into the empty AMC slot (slot A2 in this
example) and then push the release handle inward unl it stops to lock the AMC to the
LPC.
3. Add the replacement drive to the RAID 1 array. In this example, run the following
command to add drive A2 to the array:
admin@PA-7080> request
system raid slot s7 add A2
The system will automacally configure the new drive to mirror the other drive in the
RAID 1 array.
4. View the RAID status unl you see that the disk pair (S7A in this example) shows
Available and both disks show the status active sync. To view RAID status, run
the following command:
admin@PA-7080> show
system raid detail
5. The following output shows that the RAID 1 array is funconing properly:
Disk Pair S7A
Status
Disk id A1
Disk id A2
PA-7000 Series Firewall Hardware Reference
only) Install a replacement drive that is the same model as
model
: ST91000640NS
size
: 953869 MB
status
: active sync
card serial
: 002901000061
model
: ST91000640NS
size
: 953869 MB
status
: active sync
card serial
: 002901000072
Available
clean
Present
Present
173
2021 Palo Alto Networks, Inc.
©

Advertisement

Table of Contents
loading

Table of Contents