Service the PA-7000 Series Firewall Hardware
STEP 7 |
Plug the power cable into the corresponding AC power module on the back of the chassis
and turn on the power switch. The new power supply will turn on and the LED will turn
green.

Replace a PA-7000 Series DC Power Supply

Replace a PA-7050 DC Power Supply
Replace a PA-7080 DC Power Supply
Replace a PA-7080 DC PEM
Replace a PA-7050 DC Power Supply
STEP 1 |
Put the provided ESD wrist strap on your wrist ensuring that the metal contact is touching
your skin. Then aach (snap) one end of the ground cable to the wrist strap and remove the
alligator clip from the banana clip on the other end of the ESD grounding cable. Plug the
banana clip end into one of the ESD ports located on the front of the chassis before handling
ESD sensive hardware. For details on the ESD port locaon, see
STEP 2 |
Locate the failed power supply by viewing the system logs or by viewing the LED on the
front of the power supply. A red LED indicates a failed power supply. For details on the
power supply LEDs, see
STEP 3 |
Power off the DC power source that is connected to the failed DC power supply.
STEP 4 |
Remove the DC power cable from the failed DC power supply by squeezing the two clips on
each side of the plasc connector and then pull the connector away from the power supply.
STEP 5 |
Loosen the power supply thumb screw located at the top le of the power supply.
PA-7000 Series Firewall Hardware Reference
Interpret the PA-7000 Series Firewall Power Supply
129
PA-7050 Front Panel
(AC).
LEDs.