Service the PA-7000 Series Firewall Hardware
STEP 9 |
If you are using the drives from the failed LPC, read the steps in
before powering on the chassis.
Replace a PA-7000 Series Log Forwarding Card (LFC)
If the LFC fails, the chassis reboots and will aempt to recover the LFC. If the LFPC connues to
fail and the chassis reboots more than 3 mes in 30 minutes, it enters maintenance mode at which
me you must power off the chassis unl you replace the LFC.
There is one LFC model used for both the PA-7050 and PA-7080 firewalls and the procedure
is the same except that, on the PA-7050 firewall, you must install the LFC in slot 8 while on the
PA-7080 firewall, you must install the LFC in slot 7.
STEP 1 |
Power off the chassis and disconnect the power source to the chassis.
STEP 2 |
Put the provided ESD wrist strap on your wrist ensuring that the metal contact is touching
your skin. Then aach (snap) one end of the ground cable to the wrist strap and remove the
alligator clip from the banana clip on the other end of the ESD grounding cable. Plug the
banana clip end into one of the ESD ports located on the front of the chassis before handling
ESD sensive hardware. For details on the ESD port locaon, see
or
PA-7080 Front Panel
STEP 3 |
Loosen the thumb screws on each side of the LFC.
PA-7000 Series Firewall Hardware Reference
(AC).
154
Re-Index the LPC Drives
PA-7050 Front Panel (AC)
2021 Palo Alto Networks, Inc.
©