PA-7000 Series Firewall Installaon
Verify the PA-7000 Series Firewall LPC and NPC
Configuraon
Aer you install the front-slot cards and power on the PA-7000 Series firewall (described in
Connect Power to a PA-7000 Series
status of the Log Processing Card (LPC) and the Network Processing Cards (NPCs).
•
Verify the PA-7000 Series Firewall LPC Configuraon
•
Verify the PA-7000 Series Firewall NPC Configuraon
Verify the PA-7000 Series Firewall LPC Configuraon
Aer you install the Log Processing Card (LPC) and Advanced Mezzanine Cards (AMCs) in the
chassis, the firewall configures the first two drives on the le (A1 and A2) in a RAID 1 pair and
the second two drives (B1 and B2 on the right) in a second RAID 1 pair. If the AMCs contain 1TB
drives the total log storage capacity is 2TBs; if the AMCs contain 2TB drives the total capacity is
4TBs. The inial formang and RAID 1 configuraon will take approximately 3 minutes.
The chassis will not operate without a funconing LPC with at least one drive configured.
During normal operaon, all four drives should be installed and configured in two RAID 1
pairs.
To view the status of the RAID configuraon, run the following command:
admin@PA-7050> show system
raid detail
Confirm that at least one RAID 1 pair shows Available, which indicates that a drive pair is ready
and the LPC can receive logs. In the following output, Disk Pair S8A shows Available and
the status of the first RAID 1 is clean. The second RAID 1 pair (Disk Pair S8B) is also ready.
Disk Pair S8A
Status
Disk id A1
model
size
status
card serial
Disk id A2
model
size
status
card serial
Disk Pair S8B
Status
Disk id B1
model
size
status
PA-7000 Series Firewall Hardware Reference
Firewall), you can use the following informaon to verify the
: ST91000640NS
: 953869 MB
: active sync
: 002901000061
: ST91000640NS
: 953869 MB
: active sync
: 002901000067
: ST91000640NS
: 953869 MB
: active sync
119
Available
clean
Present
Present
Available
clean
Present
2021 Palo Alto Networks, Inc.
©