Maintenance and care: Inspection of the filter

Inspection of the filter

Introduction
Preventive maintenance is necessary at regular intervals if the unit is to operate efficiently
and optimally without unintended stoppages, and to ensure the expected service life of at
least 10 years.
It is important to notice that intervals between filter maintenance can vary according to the
specific environment, and that moving parts are wearing parts, and will need replacement
when worn.
The factory warranty only applies if it can be documented that regular preventive main-
tenance has been carried out as prescribed. The documentation can be a written logbook
containing a company stamp or equivalent.
Summary of
The filters are the only parts that the user can maintain himself.
intervals
Maintenance of the filter must as a minimum be carried out as shown here:
Interval
Six
months
Annual
Other components must be inspected at least every second year by trained professionals (see
page 40ff ). Remember to contact a trained professional for a service check regularly.
The unit has a built-in timer for its filter alarm (every six months as standard). The timer period
Filters - alarm and
for the filter alarm can be changed via the remote control or PC Tool, or it can be reset via the
inspection
alarm button
(6 months - 1 year)
When the timer expires, a filter alarm is triggered. A buzzer will sound and the LED "!" will light
up orange. (If the LED lights up red, please see Troubleshooting section on page 44.
A short beep will sound, indicating that the filter alarm has been reset correctly.
Step Action
1
2
3

Maintenance and care

Task
Check filters. Replace if necessary
Change filters
Resets the filter alarm when the alarm is triggered
Press for 5
sec.
Resets the filter timer without the timer having expired.
Remove the filters and inspect them after
the filter alarm has been triggered.
Even if only one filter is clogged, we recom-
mend replacing both filters to avoid imbal-
ance in the airflow through the unit.
NOTE: Replace the filters at least once a year,
regardless of whether they are clogged or an
alarm has been triggered.
Make sure that the filters are inserted the
right way. The arrows on the filter must point
in the direction shown here.
To be carried out by:
User
User
Illustration
11