Dantherm RCV 320 P2 Basic Manual page 22

Hide thumbs Also See for RCV 320 P2 Basic:
Table of Contents

Advertisement

VOC, humidity and
CO
sensor
2
Filters
22
The unit can be equipped with a VOC (air
quality), humidity or CO
2
sensors will continuously monitor the extract
air and adjust the airflow accordingly.
This mode of operation is called demand-
controlled mode. If an HRC Remote Control
is connected, the level will be shown in the
display using the Level 3 icon.
Demand-controlled operation will result in the desired ventilation rate with the lowest
possible electricity consumption.
Replacement filters in sets of two standard filters (ISO Coarse 75%) or of one standard filter
plus one ePM1>50% (pollen filter).