Summer mode
Fireplace mode
10
When summer mode is active, this will stop the supply air fan and only the extract air fan will
be in operation. In this case, a fresh air supply can be ensured by opening windows, doors,
etc.
NOTE: Summer mode will be deactivated automatically when the outdoor temperature
drops below 14 °C.
Long press (five seconds) - activate/deactivate summer mode
Active summer mode is indicated by a flashing light in the corresponding LED
Activation of the fireplace mode can be used when you light up the stove. The unit will then
run with positive pressure for seven minutes to prevent smoke in the living room. If the fire-
place mode is not deactivated manually, it will automatically stop after seven minutes.
d: The fireplace mode is only activated as long as the supply air temperature is above 9 °C.
Long press (five seconds) - activates/deactivates fireplace mode.
Active fireplace mode is indicated by flashing in the three fan speed LEDs