ABB TTF350 Operating Instructions Manual page 55

Field mounted temperature transmitters
Hide thumbs Also See for TTF350:
Table of Contents

Advertisement

Device
Description
parameters
Temp.
The 4 ... 20 mA
electronics
output signal
matches the
electronic unit
temperature
Unit
Select the unit of
measure for the
sensor
Measuremen
Defines the
t start
sensor
measurement
start
Measuremen
Defines the
t end
sensor
measurement
end
Damping
Configurable
condensation 63
% output signal
damping value
Factory
Configuration
reset
data is reset to
factory settings
for Pt100 3-wire,
0 ... 100°C
damping off,
override,
adjustment data
(trim high/low and
DAC adjustment
values are reset
to factory
settings)
Device reset
Configuration
data is reset to
factory setting for
Pt100 3-wire,
0 ... 100°C
damping off,
override
Override
Generates a 22
mA high alarm
signal for sensor
or device errors
Underdrive
Generates a 3.6
mA low alarm
signal for sensor
or device errors
HART tag
Defines HART
tag name
OI/TTF350-EN
DTM parameters
HMI LCD display
parameters
<Device>
<Device Setup>
<Configuration>
<Input/output
<Measurement
assignment>
Type / Primary
Variable (PV)>
<Device>
<Device Setup>
<Parametrize>
<Measuring Range>
<Measuring Range
<Unit>
of PV / Unit>
<Device>
<Device Setup>
<Parametrize>
<Measuring Range>
<Measuring Range
<Lower Range Value>
of PV / Lower
Range Value>
<Device>
<Device Setup>
<Parametrize>
<Measuring Range>
<Measuring Range
<Upper Range Value>
of PV / Upper
Range Value>
<Device >
<Device Setup>
<Parametrize>
<Damping>
<Voltage Output /
Damping>
<Device>
<Device Setup> <Factory
<Maintenance>
Setting>
<Reset to Factory
Setting>
<Device>
<Maintenance>
<Device Reset>
<Device>
<Process Alarm> <Fault
<Parametrize>
Signaling>
<Current Output /
Output with Fault>
<Device>
<Process Alarm> <Fault
<Parametrize>
Signaling>
<Current Output /
Output with Fault>
<Device>
<Communication>
<Maintenance>
<HART Tag>
<Poll Address /
Tag>
2-sensor input functionality / Dual sensor mode
Effective range
Temp. electronics
°C, °F, °R, K, user, mV, Ω, mA
Depending on sensor type
Depending on sensor type
0 ... 100 s
Yes / OK
Override
Underdrive
8 characters, alphanumeric
TTF350
Safety information
Check safety
function
Depending on
sensor type
Depending on
sensor type
Depending on
sensor type
Depending on
sensor type
Safety function for
potential risk all
configuration and
adjustment data are
reset to the factory
default
Safety function for
potential risk
configuration data is
reset to the factory
default
Check safety
function
Check safety
function
Check safety
function
55

Advertisement

Table of Contents
loading

Table of Contents