CSA and FM
Intrinsically safe
FM
Class I, Div. 1 + 2, Groups A, B, C, D T6
Class II, Groups E, F, G; Class III
Class I, Zone 0, AEx ia IIC T6
Product variant: TTF350-L4 .. H
Control drawing: TTF350-L4 .. H
CSA
Class I, Div. 1 + 2, Groups A, B, C, D
Class II, Groups E, F, G; Class III
Product variant: TTF350-R4 .. H
Control drawing: TTF350-R4 .. H
Non-incendive
FM
Class I, Div. 2, Groups A, B, C, D
(Class II, Groups E, F, G; Class III
Product variant: TTF350-L5 .. H
Control drawing:TTF350-L5 .. H (2 pages)
CSA
Class I, Div. 2, Groups A,B,C,D
(Class II, Groups E, F, G; Class III
Product variant: TTF350-R5 .. H
Control drawing: TTF350-R5 .. H (2 pages)
Dust-explosion protection:
TTF350-D1 ... : Dust-explosion protection
Dust / Zone 20:
Designation:
"Ex mark" II 1 D IP 65 T 135°C
EC prototype test certificate BVS06 ATEX E029
Wechsel ein-auf zweispaltig

Approvals

13 Approvals
Wechsel ein-auf zweispaltig

13.1 TTF350

TTF350
CE mark
The TTF350 including type B LCD display / configuration software
meets all requirements for the CE mark in accordance with IEC
61326 (2002).
Namur
The TTF350 including type B LCD display / configuration software
complies with NAMUR NE 21 (02/2004).
Wechsel ein-auf zweispaltig
OI/TTF350-EN
TTF350-D2 .. H: Dust-explosion protection + Intrinsic safety
Dust / Zone 20 + Gas / Zone 0:
Designation:
"Ex mark" II 1 D IP 65 135°C
"Ex mark" II 1G EEx ia IIC T6
EC prototype test certificate BVS06 ATEX E029
EC prototype test certificate PTB 05 ATEX 2017 X
EC prototype test certificate ZELM 07 ATEX 0331 U
Flameproof protection
TTF350-E3...: flameproof protection
Zone 1:
Designation:
"Ex mark" II 2G EEx d IIC T6
EC prototype test certificate ATEX
TTF350-E4 .. H: flameproof protection + intrinsic safety
Zone 1:
Designation:
"Ex mark"
"Ex mark"
EC prototype test certificate ATEX
EC prototype test certificate PTB 05 ATEX 2017 X
EC prototype test certificate ZELM 07 ATEX 0331 U
Explosion-proof protection
TTF350-L3 ... FM Explosion-proof
XP,NI, DIP Class I, II, III, Div. 1 + 2, Groups A-G, factory sealed
Control drawing: TTF350-L3
TTF350-R3 ... CSA Explosion-proof
XP,NI, DIP Class I, II, III, Div. 1 + 2, Groups A-G, factory sealed
Control drawing: TTF350-R3
Ignition protection
The TTF350 meets requirements for ATEX, FM and CSA. For
additional information, refer to the section "Explosion-protection
relevant information".
SIL: Functional safety (optional)
acc. to IEC 61508.
Device with certificate of conformity for use in safety-relevant
applications, including SIL Level 2. For additional information, refer to
the SIL safety manual for the TTH300 / TTF300 / TTF350.
TTF350
II 2G EEx d IIC T6
II 1G EEx ia IIC T6
65