DIMeNSIONS AND WeIGHTS

3.4.1 control cabinet installation

The power dissipation for the control cabinet dimension is to be taken from the technical
data.
Mounting distances
A
D
F
B
Figure 4:
Mounting distances

3.4.1.1 Ventilation in the control cabinet

If construction-conditioned the control cabinet cannot be without indoor ventilation, ap-
propriate filters must avoid suction of foreign objects.
Direction of the air
flow
Figure 5:
Control cabinet ventilation
E
D
C
Installation of the drive converter
For reliable operation, the drive converter must be mounted without clearance
on a smooth, closed, bare metal mounting plate.
Coolant inlet
Dimension
Distance in mm
A
150
B
100
C
30
D
0
E
0
F
50
1)
Distance to preceding elements in the control cab-
1)
inet door.
Front and side view of the coolant inlet
Coolant outlet
Distance in inch
6
4
1.2
0
0
2
33