Operating Modes (Functional Sequences); Explanation Of Symbols - EWM tigSpeed continuous drive 45 coldwire Operating Instructions Manual

Wire feed unit
Hide thumbs Also See for tigSpeed continuous drive 45 coldwire:
Table of Contents

Advertisement

5.1.16 Operating modes (functional sequences)

Torch trigger 1 (BRT 1) switches the welding current on or off.
Torch trigger 2 (BRT 2) switches the wire feeding on or off.
In addition, you can inch the wire by pressing torch trigger 2 (BRT 2) or reverse inch the wire by tapping
it.
You can choose between four operating modes (see the following functional sequences). Wire feeding is
infinitely adjustable by means of torch triggers 3 and 4 (BRT 3 and BRT 4).

5.1.16.1 Explanation of symbols

Symbol
Meaning
Press torch trigger
Release torch trigger
Tap torch trigger (quick pressing and releasing)
Shielding gas flowing
Welding performance
I
Non-latched, manual
Latched, manual
Non-latched automatic
Latched automatic
Time
t
Start program
P
START
Main program
P
A
Reduced main program
P
B
End program
P
END
Wire feeding
099-000237-EW501
25.04.2019
Design and function
Figure 5-22
Transport and installation
45