Technical data

Fax + 1-801-956-2401
This device complies with RSS 210 of Industry Canada.
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of this
device.
L' utilisation de ce dispositif est autorisée seulement aux conditions suivantes:
(1) il ne doit pas produire d'interference et
(2) l' utilisateur du dispositif doit étre prêt à accepter toute interference radioélectrique reçu, même si celle-ci est
susceptible de compromettre le fonctionnement du dispositif.
Caution: Exposure to Radio Frequency Radiation.
The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit
RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from
Health Canada's website
http://www.hc-sc.gc.ca/rpb.
Responsible party:
Otto Bock Healthcare Canada Ltd.
5470 Harvester Road
L7L 5N5 Burlington, Ontario
Canada
Phone + 1-800-665-3327
Caution: Federal law (USA) restricts this device to sale by or on the order of a practitioner licensed by law of the
State in which he/she practices to use or order the use of the device.
16 Technical data
Environmental conditions
Transportation in original packaging
Transportation without packaging
Storage (≤3 months)
Long-term storage (>3 months)
Operation
Charging the battery
Product
Reference number
Mobility grade according to MOBIS
Maximum body weight
Protection class
Water resistance
Prox. system height to alignment reference point 3B5-3*
(pyramid adapter)
Prox. system height up to alignment reference point
3B5-3=ST* (threaded connector)
48
-25°C/-13°F to +70°C/+158°F
-25°C/-13°F to +70°C/+158°F
Max. 93% relative humidity, non-condensing
-20°C/-4°F to +40°C/+104°F
Max. 93% relative humidity, non-condensing
-20°C/-4°F to +20°C/+68°F
Max. 93% relative humidity, non-condensing
-10°C/+14°F to +60°C/+140°F
Max. 93% relative humidity, non-condensing
+10°C/+50°F to +45°C/+113°F
3B5-3*/3B5-3=ST*
3 and 4
125 kg
IP66/IP68
Maximum water depth: 3 m
Maximum time: 1 hour
Waterproof, resistant to corrosion, resistant to penetra­
tion from water jets
0 mm
26 mm
Genium X3 3B5-3/3B5-3=ST