Technical data
4 Technical data
4.1 Dimensions and weight
14
4.2 Electrical data
15
4.3 Pneumatic data
Compressed air supply from customer
Working pressure of the machine
4.4 Noise emissions
Sound pressure level
Measurement method
Hearing protection
14
Dust-free, dry and oil-free compressed air
6 – 10 bar
3 bar
Noise measurement in idle condition
65,9 dBA
free field at a distance of 1 m to machine at a height of
1.6 m
not required
701Z42=1-1, 701Z42=1-4