Martin ELP WW LED Profile User Manual page 31

Table of Contents

Advertisement

Thermal
Cooling .............................................................. Forced air (temperature-regulated, low noise)
Maximum ambient temperature (Ta max.) ......................................................... 40° C (104° F)
Minimum ambient temperature (Ta min.) ............................................................... 0° C (32° F)
Total heat dissipation (calculated, +/- 10%, at full intensity, full white) ................ 1000 BTU/hr.
Approvals
EU safety ................................................ EN 60598-2-17 (EN 60598-1), EN 62471, EN 62493
EU EMC .............................. EN 55015; EN 55032; EN 55103-2; EN 61000-3-2,-3; EN 61547
US safety ...................................................................................................................... UL 1573
US EMC ................................................................................................... FCC Part 15 Class B
Canadian safety ......................................................................................... CSA C22.2 No. 166
Canadian EMC .............................................................. ICES-003 Class B, ICES-005 Class B
Australia/NZ ...................................................................................................................... RCM
Included Items
Power cable 1.5 m without power plug
Mounting bracket
Accessories
Cables, 16 A, for connection to power in chains:
Power input cable, H07RN-F, 2.5 mm2, 14 AWG, bare ends to Neutrik
TRUE1 NAC3FX-W (female), 1.5 m (4.9 ft.) ..................................................... P/N 91611797
Power input cable, H07RN-F, 2.5 mm2, 14 AWG, bare ends to Neutrik
TRUE1 NAC3FX-W (female), 5 m (16.4 ft.) ....................................................... P/N 91611786
Link Cable, H07RN-F Neutrik TRUE1-TRUE1 0.45 m (1.5 ft.) .......................... P/N 91611784
Link Cable, H07RN-F Neutrik TRUE1-TRUE1 1.2 m (3.9 ft.) ............................ P/N 91611785
Link Cable, H07RN-F Neutrik TRUE1-TRUE1 2.5 m (8.2 ft.) ............................ P/N 91611796
Power connectors:
Neutrik PowerCON TRUE1 NAC3MX-W (male) ................................................ P/N 91611788
Neutrik PowerCON TRUE1 NAC3FX-W (female) ............................................. P/N 91611789
Lens Tube Options (see below for part numbers):
Martin ELP Lens Tube: 19°
Martin ELP Lens Tube: 26°
Martin ELP Lens Tube: 36°
Martin ELP Lens Tube: 50°
Ordering Information
Martin ELP WW (Body Only) in cardboard box ............................................. P/N 9045107781
Martin ELP Lens Tube: 19° in cardboard box .............................................. P/N 9045107782
Martin ELP Lens Tube: 26° in cardboard box .............................................. P/N 9045107783
Martin ELP Lens Tube: 36° in cardboard box .............................................. P/N 9045107784
Martin ELP Lens Tube: 50° in cardboard box .............................................. P/N 9045107785
Specifications are subject to change without notice. For the latest product specifications, see www.martin.com
Disposing of this product
Martin™ products are supplied in compliance with Directive 2012/19/EC
of the European Parliament and of the Council of the European Union on
WEEE (Waste Electrical and Electronic Equipment), where applicable.
Help preserve the environment! Ensure that this product is recycled at
the end of its life. Your supplier can give details of local arrangements for
the disposal of Martin products
Martin ELP WW Profile user guide
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elp ww

Table of Contents