Set All Settings To Factory Default; Fixture Test; Fixture Information; Viewing Live Dmx Values - Martin ELP WW LED Profile User Manual

Table of Contents

Advertisement

Press ENTER to confirm.
Display
This option allows you to set some parameters for the display screen.
Select DISPLAY from the PERSONALITY menu and press ENTER to confirm.
Use the UP and DOWN buttons to select:
DISPLAY SLEEP – Use the UP and DOWN buttons to select display sleep time, settings
are ON (Display permanently on), 2 MINUTES, 5 MINUTES or 10 MINUTES
DISPLAY ROTATION –Use the UP and DOWN buttons to select Normal (Display
orientation normal) or ROTATE 180(Display orientation rotated 180°)
DISPLAY INTENSITY –Use the UP and DOWN buttons to adjust display intensity from
10%-100% (default = 100%)
TEMPERATURE UNIT – Use the UP and DOWN buttons to select °C or °F
Press ENTER to confirm.

Set all settings to factory default

To return all settings to factory default, select DEFAULT SETTINGS and press ENTER to confirm,
FACTORY DEFAULT will show on the display. Press ENTER again.
Use the UP and DOWN buttons to select NO (cancel) or YES (return all settings except
calibrations to factory defaults).
Press ENTER to confirm (or press MENU to exit without making a change).

Fixture Test

This menu allows you to run self test sequences on the fixture's LED emitters. A sequence of LED
test, dimmer test, strobe test will be run.

Fixture information

The INFORMATION menu allows you to view various fixture information: Power on time, LED
hours, Software version, Fixture ID, RDM unique ID, Fan speeds, temperatures.

Viewing live DMX values

This menu allows you to view the current DMX values for any function.
Select the DMX LIVE menu and press ENTER.
Use the UP and DOWN buttons to select the function you wish to view.

Setting control values manually

You can manually set control values. This may be useful when testing, or to use the fixture in a
static setting without a DMX controller.
This menu also allows you to reset the fixture.
Reset
To reset the fixture, go to the MANUAL CONTROL menu and press ENTER. Use the UP and
DOWN buttons to select RESET and press ENTER again.
Then use UP and DOWN to select YES, and press ENTER to activate.
Setting values
Go to the MANUAL CONTROL menu and press ENTER. Use the UP and DOWN buttons to select
the function you wish to control.
Once you have selected a function, press ENTER, then use the UP and DOWN buttons to select a
value from 0 to 255.
Press MENU to go back up and select a different function to control.
18