5.4

Parameter Settings

To change the truck setting you must enter the master code.
Z
The factory setting for the master code is 7-2-9-5.
M
When starting the truck for the first time, change the master code (see section 5.1).
F
Safety notes for trucks with indicator instrument (CANDIS (o))
– Parameter settings must be made carefully and only by special trained personnel .
If in doubt, consult the manufacturer's service department.
– Each setting must be monitored on the LC display of the display instrument
(CANDIS (o)). If in doubt, cancel the setting by pressing the o-key (26).
– Since changing any parameter will affect the truck's travel pattern, you must carry
out a test run in a specially designated work area.
To enter the master code:
– Press theo key
– Enter master code
Service hours
are displayed
Code Lock Parameters
Setting procedure for trucks without a display instrument (CANDIS (o)):
– Enter the three digit parameter number, confirm with the Set key (22).
– Enter the setting according to the parameter list or change and confirm with the Set
key (22).
Z
If the entry is incorrect, the LED (23) of the o key (26) goes red. If you enter the
parameter number again the setting can be entered or changed.
To enter more parameters, repeat the procedure. To finish entering, press the o key
(26).
E 20
Display instrument
(CANDIS)
284.0
LED (21)
LED (23)
o key
Key 1
Green
Off
Flashing
LED (24)
LED (25)
Key 2
Key 3
Off
Off

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ece 225Ece 220xlEce 225xl

Table of Contents