SERVICE MANUAL
ELECTRICAL SYSTEM

FUSE CHECK/REPLACEMENT

1.
Disconnect the battery connector (12).
2.
Move aside the recovery water drain hose (16).
3.
Remove the battery charger cable (I) from the cable holder (J).
4.
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the panel
(B).
5.
Check/replace the following fuses:
(C) - F1 fuse, deck: (40 A)
(D) - F2 fuse, vacuum system: (30 A)
(E) - F3 fuse, drive system: (30 A) (*)
(F) - F4 fuse, signal circuits: (3 A)
(G) - F5 fuse, brush/pad-holder release: (20 A) (*)
(H) - F6 fuse, pumps: (3 A) (*)
(*) Only for Adfinity
X20R, 20D, X20D, X20C, X24D
TM
6.
Perform steps 1 to 4 in the reverse order.