BRUSH MOTOR CARBON BRUSH CHECK/REPLACEMENT (For Adfinity™ X24D)
Check
1.
Remove the deck (see the procedure in the relevant paragraph).
2.
At the workbench, remove dust and debris from the motor, especially in the area of the carbon brushes.
3.
Remove four protection covers (A) by disengaging the fasteners.
4.
Remove the carbon brush nuts (B) with the lead-in wires.
5.
Disengage the tabs (C) and remove the carbon brushes (D).
6.
Check if the carbon brushes (D) are worn. Replace the carbon brushes when: the contact with the motor armature is
insufficient, the carbon brushes are worn, the carbon brush contact surface is not integral, the thrust spring is broken, etc.
Replace the carbon brushes as an assembly.
Reset
7.
Assemble the components in the reverse order of disassembly.
A
Adfinity™ 17ST / 20ST / X20R / 20D / X20D / X20C / X24D
SERVICE MANUAL
BRUSHING SYSTEM
B
D
C
9096982000
ENGLISH
A
C
S301543A
47