SOLUTION/CLEAN WATER SUPPLY SYSTEM

SOLUTION/CLEAN WATER TANK AND SUPPLY SYSTEM CLEANING

1.
Drive the machine to the appointed solution disposal area.
2.
(For Adfinity™ X20R, 20D, X20D, X20C, X24D) Turn the ignition key (80) to "0".
(For Adfinity™ 17ST, 20ST) Turn off the switches (71) and (73).
3.
Empty the solution/clean water tank (20) with the hose (17).
4.
Start the machine (as shown in the User Manual) and keep it running until the solution/clean water tank is completely empty.
5.
(For Adfinity™ X20R, 20D, X20D, X20C, X24D) Turn the ignition key (80) to "0".
(For Adfinity™ 17ST, 20ST) Turn off the switches (71) and (73).
6.
Clean the tank (20) with clean water.
7.
Start the machine (as shown in the User Manual) and keep it running until the solution/clean water tank is completely empty.
8.
Clean the solution filter (see the following procedure).
SOLUTION FILTER CLEANING (For Adfinity™ 17ST, 20ST)
1.
Drive the machine on a level floor.
2.
Turn off the switches (71) and (73).
3.
Close the solution tap (A) under the machine left lower side. The tap (A) is closed when it is on the position (B) and it is open
when it is on the position (C).
4.
Remove the transparent cover (D), then remove the filter strainer (E). Clean and install them on the support (F).
NOTE
The filter strainer (E) must be correctly positioned on the housing (G) of the support (F).
5.
Open the tap (A).
G
E
Adfinity™ 17ST / 20ST / X20R / 20D / X20D / X20C / X24D
F
E
D
SERVICE MANUAL
SOLUTION/CLEAN WATER SUPPLY SYSTEM
ENGLISH
A
C
21
9096982000
B
S301520A