Detergent Tank Cleaning (For Adfinity™ X20R, X20D, X20C, X24D); Ecoflex™ System Draining (For Adfinity™ X20R, X20D, X20C, X24D) - Advance acoustic Adfinity 17ST Service Manual

Hide thumbs Also See for Adfinity 17ST:
Table of Contents

Advertisement

ENGLISH
SERVICE MANUAL
ECOFLEX™ SYSTEM
DETERGENT TANK CLEANING (For Adfinity™ X20R, X20D, X20C, X24D)
1.
Drive the machine to the appointed detergent disposal area.
2.
Turn the ignition key (80) to "0".
3.
Open the cover (22) and check that the recovery water tank (21) is empty, otherwise empty it with the drain hose (16). Close
the cover (22).
4.
Grasp the handle (41) and carefully lift the tank (40).
5.
Unscrew the union and remove the hose (48) from the tank (45).
6.
Remove the tank (45) by releasing it from the fasteners.
7.
Unscrew the plug (A) and wash the detergent tank (B) in the appointed detergent disposal area. If necessary, remove the
supply hose (C) and clean it, especially in area of the vacuum end pipe (D). Install the supply hose (C).
8.
Check that the plug vent hole (E) is not clogged, by driving in air and checking if it comes out from the outer hole (F). If
necessary clean the hole with compressed air. Install the plug (A).
9.
Install the tank (45) and connect it to the hose (48).
10. When the detergent tank and the supply hose have been drained, the EcoFlex™ system must be drained too (see the
procedure in the following paragraph).
ECOFLEX™ SYSTEM DRAINING (For Adfinity™ X20R, X20D - X20C - X24D)
1.
Clean the detergent tank, then remove the detergent remained in the hoses and in the pump.
2.
Grasp the handle (41) and carefully lower the tank (40).
3.
Turn on the machine by turning the ignition key (80) to "I".
4.
Turn on the EcoFlex™ system by pressing the switch (77). Check that the switch warning led (78) turns on.
5.
Press the switches (77) and (82a) at the same time, until the switch warning led (78) starts flashing (after about 5 seconds).
6.
Release the switches and wait for the warning led (78) to stop flashing and for the vacuum system to turn on.
7.
Collect the detergent remained on the floor.
8.
Turn the ignition key (80) to "0".
9.
Grasp the handle (41) and carefully lift the tank (40), then check that the hose (48) is empty, otherwise perform steps 3 to 9
again.
NOTE
The draining cycle lasts about 30 seconds, then the vacuum function automatically turns on, which allows to remove the
detergent remained. The draining cycle can also be performed with the detergent tank (45) full of water, thus cleaning the
system thoroughly.
It is advisable to perform the draining cycle when the EcoFlex™ system is really dirty/encrusted because the machine
has not been used/cleaned for a long time.
The draining cycle can be performed also to quickly fill the detergent supply hose when the tank (45) is full but the
system is still empty.
If necessary, the draining cycle can be repeatedly performed.
26
9096982000
E
Adfinity™ 17ST / 20ST / X20R / 20D / X20D / X20C / X24D
C
F
A
D
B
S301525A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents